Home  -  Products  -  Atomic Absorption Spectrophotometer > 单火焰原子吸收 > Three-lamp flame atomic absorption spectrometer
Three-lamp flame atomic absorption spectrometer
 Three-lamp flame atomic absorption spectrometer
 Three-lamp flame atomic absorption spectrometer
 Three-lamp flame atomic absorption spectrometer
 Three-lamp flame atomic absorption spectrometer
 Three-lamp flame atomic absorption spectrometer
 Three-lamp flame atomic absorption spectrometer
 Three-lamp flame atomic absorption spectrometer
 Three-lamp flame atomic absorption spectrometer

Product Parameters

flame,atomic absorption spectrometer

Attribute
Product Name
Model
Brand
Visits
Update Time
Details
Three-lamp flame atomic absorption spectrometer
CAAM-2001F
HTH Instrument
1261 Click
2024-11-26

Product Details

The CAAM-2001F three-lamp flame atomic absorption spectrometer was independently developed by our company professors Wu Tingzhao and Chen Lianyuan, who worked on developing this instrument, have been in the atomic absorption field in China for many years and have experience in developing various types of instruments. They brought together years of experience and dedicated it to the field of atomic absorption spectroscopy.

I.Detection Methods of Atomic Absorption Spectrometer and Theoretically Measurable Trace Elements: (For reference only)

1. Atomic Absorption Flame Method:

The atomic absorption flame method (air–acetylene) can detect elements at the PPM level. Sodium (Na), potassium (K), magnesium (Mg), calcium (Ca), chromium (Cr), manganese (Mn), iron (Fe), cobalt (Co), nickel (Ni), platinum (Pt), gold (Au), copper (Cu), silver (Ag), zinc (Zn), cadmium (Cd), lead (Pb), bismuth (Bi), etc.

2. Atomic Absorption Hydride Method:

The atomic absorption hydride method can perform trace detection (PPb level) for low-melting-point elements. Measured elements include arsenic (As), selenium (Se), antimony (Sb), bismuth (Bi), lead (Pb), tin (Sn), tellurium (Te), germanium (Ge), mercury (Hg), etc. (A hydride generator needs to be purchased separately)

II. Application Scope of Atomic Absorption Spectrometer:

Atomic absorption spectrometers are widely used for testing and analysis in various industries, including hospitals, pharmaceuticals, steel, health and epidemic prevention, metal smelting, geology and mining, chemical industry, water quality monitoring, food and dairy, environmental monitoring, quality inspection, drug testing, agriculture, toys, electronics, and more.

1. Main technical specifications of atomic absorption spectrometers

1.1 Spectroscopy system

1.1.1 Grating marking: 1800 lines/mm.

1.1.2 Wavelength range: 190-900nm.

1.1.3 Spectral bandwidth: Five automatic adjustable levels: 0.1,0.2,0.4,1.0,2.0nm.

1.1.4 Wavelength length: ≤0.15nm, wavelength repeatability: ±0.05nm.

1.1.5 Baseline drift: Static ≤ 0.002A/30 minutes, Dynamic ≤ 0.004A/30 minutes.

1.1.6 Light Source: Three-lamp position automatic turret switching and automatic alignment.

1.1.7 High-Performance Power Supply: Built-in high-performance lamp dual cathode power supply is used to measure edge energy spectral interference and unstable elements such as arsenic, selenium, and mercury. High-performance dual cathode emission increases luminous intensity, extends lamp service life, and enhances instrument testing stability and sensitivity.

1.1.8 The instrument light source lamp frame turret uses dual synchronous wheel technology for control, with a lifting degree to ensure smooth and reliable operation of the lighthouse.

1.1.9 The instrument's external optical path uses a focused semi-transparent, semi-reflective device to combine the effective background light source with the main light path, improving the accuracy and stability of analysis data.

1.1.10 The monochromator uses worm gear transmission to control the splitting system, greatly improving the resolution accuracy of the optical path and significantly enhancing the wavelength accuracy of the element to be scanned during scanning

2.2 Flame Atomizer

2.2.1 Characteristic Concentration (Cu): 0.015 μg/mL/1%.

2.2.2 Detection Limit (Cu): 0.002 μg/mL.

2.2.3 Precision: RSD ≤ 0.5%.

2.2.4 Burner Head: Titanium metal burner head.

2.2.5 Nebulizer: Wu-type high-efficiency glass nebulizer.

2.2.6 Atomization Chamber: Explosion-proof high-polymer material atomization chamber.

2.2.7 Adjustment System: Fully automatic PC-controlled flame/graphite furnace switching, with automatic optimization and automatic ignition.

2.2.8 Safety Protection: Features automatic safety protection, anti-flashback automatic gas protection, acetylene leak alarm, automatic shutdown system, and automatic power-off in case of abnormalities.

III. Main Features of the CAAM-2001 Series Atomic Absorption Spectrometer:

1. High Stability:

   The instrument's baseline stability is ≤0.002A/30min. Baseline stability is a fundamental indicator for evaluating an instrument, as it determines a series of operational conditions of the main unit, such as noise, sensitivity, and repeatability.

2. High Sensitivity:

   The atomic absorption spectrometers produced by our company can achieve sensitivity (1 μg/mL copper Cu absorbance ≥0.28 Abs).

3. High Power:

   The lamp current of the instrument is controlled at 3mA–5mA (other manufacturers 8mA–12mA), spectral bandwidth is 0.2nm, and a negative high voltage of 150V–350V is enough to reach full transmittance. This allows your hollow cathode lamp to be used more than half longer, greatly saving consumables and procurement costs.

4. USB Interface:

   This atomic absorption spectrometer is equipped with a USB interface, compatible with various computer models and office equipment, reflecting the instrument's foresight and compatibility.

5. Independently Developed Supporting Equipment and Consumables:

   Our company independently develops ancillary facilities and consumables related to atomic absorption spectrometers, such as hydride generators, high-performance hollow cathode lamps, and glass efficient nebulizers. The use of high-performance hollow cathode lamps offers advantages such as high emission intensity, high determination sensitivity, lower detection limits, better stability, and elimination of interference from nearby spectral lines. The development, production, and application of glass efficient nebulizers improve the sensitivity, detection limits, and stability of atomic absorption measurements to a certain extent. The flow injection hydride generator used in atomic absorption spectrometers is easy to operate, offers high determination efficiency, and can partially replace atomic fluorescence photometers.

6. User-Friendly Data Processing Software:

   Combining domestic and international data processing results with practical experience in the Chinese atomic absorption spectroscopy field, it provides highly reliable data processing outcomes. The software is designed for fast and easy operation with strong functionality.

7. Integrated Graphite Furnace System with Main Unit:

   The graphite furnace system automatically switches with the flame atomizer (H-type), making the transition from system switching to sample measurement very simple and fast, greatly saving analysis time. An automatic sampler is optionally available.

.Which Industries Using the Instruments and the Elements They Test for:

1. Hospitals: Mainly measure the content of elements like copper, iron, calcium, magnesium, zinc, selenium, lead, arsenic, cadmium, sodium in blood, urine, hair, etc.

2. Pharmaceutical Companies: Mainly measure the content of lead, cadmium, arsenic, mercury, copper, calcium, magnesium, zinc, etc., in medicines.

3. Metallurgy Industry: Measure cobalt, manganese, vanadium, iron, calcium, magnesium, nickel, sodium in ferroalloys. Measure aluminum, iron, manganese, lead, tin, antimony, silicon, nickel, tin, zinc in copper ingots.

4. Measure lead, arsenic, mercury, copper, iron, calcium, magnesium, cadmium, etc., in food.

5. Measure arsenic, cadmium, chromium, mercury, lead, antimony, selenium, barium, etc., in toys.

6. Measure boron, iron, manganese, copper, zinc, lead, arsenic, mercury, etc., in soil.

7. Measure harmful elements like lead, chromium, cadmium, mercury, barium, etc., in home appliances and electronic materials.

8. Measure the ion content of potassium, sodium, magnesium, aluminum, iron, zinc, copper, lead, manganese, etc., in ion polymers.

9. Measure metal ions like copper, zinc, lead, cadmium, hexavalent chromium, total chromium, calcium, magnesium, potassium, sodium, nickel, manganese, etc., in water.